we could supply good quality goods, aggressive cost and very best purchaser assistance. Our destination is "You come here with difficulty and we supply you with a smile to take away" for Co2 Laser Tube,Laser Co2 Cutter,High Power Laser. we sincerely welcome shoppers all around the globe to cooperate with us.

China for CNC Laser Cutter W4  CO2 Laser Tube Operating Instruction export to Greece Manufacturers

W4 Operation Instruction


CO2 laser tube is main part for laser machine which are included  CO2 laser engraving machineCO2 laser engraving machinelaser cutterlaser engraver which can cut wood ,acrylic and so on 

1.    Installation Requirement

CO2 laser tube is main part for laser machine which are included  CO2 laser engraving machineCO2 laser engraving machinelaser cutterlaser engraver 



Make sure to follow the operation instruction of model W4 as shown in the illustration. The dedicated power P14 should be equipped. The positive pole of laser tube is in high voltage (the ignition voltage is 24kv). It may cause the following consequence when it is failed to follow the instruction: Arcing; the inner tube will be punctured by electricity and may cause water leakage.

2.    Operation conditions

Water cooling: using purified water; 3 to 5 liter/minute; water temperature: 10-40.

The operating environment: temperature 2-40; humidity 10-60%.

The working current: test current is 30mA. Maximum working current is 30mA. The running current must be kept below 28mA. The life span can reach 10,000 hours if the current is kept below 26mA. The ammeter must be connected to the negative electrode of laser tube.

When it is working under over-high current for long term, the negative pole will appearbrown yellowand the life span will be shortened rapidly.

To protect dust from going into the insulation sheath, please wrap it with plastic film.

3.    Working Performance

Cutting function.

Engraving function: Very good. When the working current is 4mA and the tube is in the state of preionization, the laser can be used for high-frequency impulse engraving.

4.    Key Notes

Do not clean the exterior surface of the output widow mirror with tools such as tampon; otherwise the output power will be seriously affected. The followings are the designated methods to clean up pollution in the exterior surface of window mirror:

1) When the mirror is polluted, do not turn on the laser.

2) Blow the mirror surface sideways with an air blower.

3) Spray the pure alcohol on the mirror surface with sprayer.

4) Turn on the laser after the alcohol gets fully volatilized.

5) If the methods above don't work effectively, it is necessary to ask for the professional to use tampon with alcohol to clean the mirror surface from middle to edge. The best solution is to prevent the window from being polluted.

 

Attention: it is forbidden to clean the mirror with acetone.

The screws in the front and back ends of the laser tube are not allowed to be moved, otherwise the out power will be declined, even the tube will be scrapped.

Put the acryl 300mm far away from output mirror, when testing its laser spot. 

5.    Safety

The laser beam is invisible light. Please wear protective glasses when debugging the laser. The positive pole is in high voltage. Pay attention to the security marks. 

6.    Storage and Transportation Requirement

Pour out cooling fluid in the event of storage and transportation, and cover the output terminal with a dust-proof plastic bag. The storage environment is 2-40, and the requested humidity is 10-60%. Pack the laser as in the original way.

Important notes: it is requested to use adhesive tape to cement the sponge together with laser tube to prevent the tube from vertically sliding during transportation. The sponge in the side of output mirror must be 70 mm beyond it, and the sponge in the side of reflecting mirror must be 50 mm wider.

 

   Tubes operated in wrong way are not guaranteed by Manufacturer.

"To become the stage of realizing dreams of our employees! To build a happier, a lot more united and more expert workforce! To reach a mutual profit of our buyers, suppliers, the society and ourselves for W4 CO2 Laser Tube Operating Instruction. The product will supply to all over the world, such as: Albania,Cyprus,India. Our solutions have national accreditation requirements for qualified good quality products affordable value was welcomed by individuals all over the world. Our products will continue to improve inside the order and appear forward to cooperation with you Definitely should any of those goods be of curiosity to you be sure to letus know. We'll be satisfied to supply you a quotation up on receipt of the detailed needs.